The following link will take you to information regarding an Underground Single Phase Line Extension/New Construction:
Cost to Member
-
Meter loop/Meter can;
-
URD service wire, 4/0 or 350 service wire available, please see products list for current pricing;
-
Note: Cost is for wire only. Installation is member's responsibility.
-
Restrictions
-
All service must meet National Electric Code; HOTEC reserves the right to disallow any service not up to NEC or HOTEC specifications;
-
Underground service must be buried a minimum of 24 inches;
-
HOTEC will extend 125 ft. of secondary service from transformer. If service has not yet made contact with the home’s electrical entrance there will be a meter pedestal set at this point or any point between the transformer and the 125 ft. secondary extension;
-
If a service extends past 125 ft. the customer will be responsible for installing all secondary wire and conduit past the point of the pedestal;
-
Owner or builder will be responsible for any trenching, bedding, or backfill. All trenching, bedding, and backfill must be approved by HOTEC.
To view the specification sheet for a 200 Amp Meter Loop, click the link below:
To view the specification sheet for a 320 Amp Meter Pedestal, click the link below:
Mobile Home
Spec Sheet for Mobile Homes
Are you looking to have work done by Heart of Texas Electric at your mobile home? This is the information you will need to for any and all construction completed by HOTEC based upon our required specifications.
Non-Residential Permanent Structure
Spec Sheet for Non-Residential Permanent Structures
For more information on construction for a Overhead Single Phase Line Extension on a Non-Residential Permanent Structure, please follow the link below.
Non-Residential Permanent Structure
Permanent Residence | Site Built Home
Spec Sheet for Permanent Residence
For more information on construction for a Overhead Single Phase Line Extension on a Permanent Structure, please follow the link below.
Temporary or Seasonal Structures
Spec Sheet for Temporary or Seasonal Structures
For more information on construction for a Overhead Single Phase Line Extension for Temporary or Seasonal Structures please follow the link below.
Temporary or Seasonal Structures
Underground Single Phase 200 or 320 AMP
Spec Sheet for Underground Single Phase 200 or 320 AMP
For more information on construction for an Underground Single Phase 200 or 320 AMP, please follow the link below:
Underground Single Phase 200 or 320 AMP
Important Financial Disclosure
Important Financial Disclosure
When it comes to doing business, the cooperative may elect to charge for actual work order expense.